• High Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler Flue
  • High Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler Flue
  • High Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler Flue
  • High Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler Flue
  • High Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler Flue
  • High Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler Flue

High Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler Flue

After-sales Service: 24 Hours Online Service
Warranty: 1 Year
Brand: CD
Customized: Customized
Portable: Non Portable
Certification: CE
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Jiangsu, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
to see all verified strength labels (15)
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • FAQ
Overview

Basic Info.

Model NO.
CD-ZOY-6
Gas
O2
Type
Electrochemical Gas Analyzer
Lnstrument Accuracy
±1%
Temperature Control Accuracy
±1ºC
Display
English Display
Power Supply
100V-240V AC 50-60Hz
Service Ambient Temperature
-20ºC~+55°c
Transport Package
Box
Trademark
CD
Origin
China
Production Capacity
5000

Product Description

Product Description

 a.    OLED active illumination display makes the operation easy and convenient;
   b.    The new type zirconia sensor has a high measurement accuracy, rapid response speed, long calibration cycle, and small drift value, etc.;
   c.    With automatic temperature compensation function, the analyzer doesn't strictly require the flow for calibration compared with similar products. Flow within 300ml/min~3L/min would affect sensor's operation performance;
   d.    Measurement range can be expanded to 0~40.00% (oxygen-enriched combustion), and its range can be switched automatically;
   e.    The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range;
   f.     User could set upper and lower limits of oxygen concentration of 4-20mA and 0-5V analog output to acquire a more accurate analog output result;  
   g.    RS232 (default) or RS485 digital communication port can be selected according to clients' requirement, to realize unidirectional or bidirectional communication with computer or other digital communication facilities.

Product Parameters
Test principle zirconia
Display mode 4 bits LED display
Test range 0 ~ 10/25.00% O2
Expanded range 0 ~ 10/25/40.00% O2 (oxygen-enriched combustion)
Resolution 0.01%
Accuracy ≤±1.5%FS
Repeatability ≤±1%
Response time T90≤30S
Analog output 4~20mA.DC(non-isolated output, loaded resistance lower than 500 Ohm) 
0~5V.DC(non-isolated output, loaded resistance higher than 10k Ohm) 
1 way programmable alarm output (Dry contact type, maximum load 220VAC/2A)  
Communication Port RS232 (default) or RS485
Calibration mode online one-point calibration
Power supply AC220V±10% 50/60Hz
Operation temperature Gauge: -10 ~ +50ºC
Probe: low-temperature type,0 ~ 350ºC
mid-temperature type,0 ~ 700ºC
Install Hole Cut Φ50mm ~ Φ90mm
Connection way Cable (8 meters for standard equipment)
The length of the probe 1 meter in usual (other length customizable)
Serving life >3 years (under normal use)
Install mode inserting mount and DN65 standard flange for the probe,wall mount for the gauge
Detailed Photos

High Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler FlueHigh Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler FlueHigh Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler FlueHigh Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler FlueHigh Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler FlueHigh Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler FlueHigh Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler FlueHigh Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler FlueHigh Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler FlueHigh Temperature Resistant Zirconia Oxygen Content Analyzer for Split Boiler Flue

FAQ

FAQ:
Q1: What's your business range?
A: We manufacture PH/ORP/EC/DO/Chlorine/Turbinity meter and provide dosing pump, diaphragm pump,dosing system, pressure instrument, flow meter, level meter, dosing system and so on.
Q2: How about the quality of the managements?
A: We have a complete quality control system , all of our products will be fully pre-inspection by QC departments before shipping to you . We have the certification of ISO,CE we could send the certification test of our company to you.
Q3: Can you offer OEM or design services?
A: Yes, we have our own design department and production tools. We can make OEM products according to your requirements.
Q4: What are your terms of payment and delivery time?
A: We could accept T/T, Paypal, Western Union, Credit Assurance. Generally, we will arrange the shipment within 7 days after received payment.
Q5: How about warranty?
A: 12 months warranty. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now